Bryant KN-COPP-3-RC Guía de usuario

Busca en linea o descarga Guía de usuario para Monóxido de carbono (co) detectores Bryant KN-COPP-3-RC. Bryant KN-COPP-3-RC User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Carbon Monoxide
Alarm
Users Guide
Please have the following information
ready when calling:
CO Model number (located on back of alarm):
CO Assembly number (located on back of alarm):
Date of Manufacture (located on the back of the alarm):
Date of Purchase:
Where Purchased:
For questions concerning your Carbon Monoxide Alarm,
please call our Consumer Hotline at 1-800-880-6788
.
A
A
t
t
t
t
e
e
n
n
t
t
i
i
o
o
n
n
:
:
Please take a few minutes to thoroughly read this manual, which should be saved for future
reference and passed on to any subsequent owner. If you have any questions about the operation or instal-
lation of your alarm, please call our toll free Consumer Hotline at 1-800-880-6788.
OM19-01
810-2682 REV. A
09/05
T
E
ST
-RE
SE
T
P
E
A
K LE
VE
L
Carbon Monoxide
ALARM
PA
R
T
S P
E
R
M
ILLION
OF C
O
(Lb = Low
or N
o Ba
tte
r
y)
IAS 6-96 2ND EDITION CO ALARM
ALSO COMPLIES WITH CSA 6.19-01
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
See page
23 for “What to do when
the alarm sounds”
BRYANT CO Alarm with
Digital Display and Peak Level Memory
Model: KN-COPP-3-RC
Assembly: COALMCCNRB01-A
US
IAS 6-96 SECOND EDITION CO ALARM
ALSO COMPLIES WITH CSA 6.19-01
Vista de pagina 0
1 2 3 4 5 6 ... 34 35

Indice de contenidos

Pagina 1 - Carbon Monoxide

Carbon MonoxideAlarmUser’s GuidePlease have the following informationready when calling:CO Model number (located on back of alarm):CO Assembly number

Pagina 2 - Table of Contents

What Carbon Monoxide Alarms Can and Cannot DoCO alarms are designed to sense unacceptable levels of CO frommalfunctioning furnaces, appliances, gas en

Pagina 3 - WARNING!

InstallationWhere to Install Your CO AlarmYour Bryant CO alarm should be mounted in or near bedrooms and livingareas. It is recommended that you insta

Pagina 4 - Quick Set Up Guide

Where Not to Install Your CO AlarmTToo aavvooiidd ccaauussiinngg ddaammaaggee ttoo tthhee uunniitt,, ttoo pprroovviiddee ooppttiimmuumm pprrootteecctt

Pagina 5

Installation Avoid the following: • Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions, such as: 1)

Pagina 6 - Introduction

Installation If the outlet is mounted horizontally (sideways):If you are going to use your alarm as a direct plug and you are going toplug in to an ou

Pagina 7

For a wall-mounted unit, you will need to pull out the removable adapterand power cord. To install:1. Follow steps 1 through 4 in the previoussection

Pagina 8

Battery Installation13Note: This alarm is shipped from the factory with the battery dis-connected from the alarm.Battery Installation and OperationIns

Pagina 9

Battery Backup OperationWhen the alarm is unplugged or loses AC power and the battery pack is fullycharged, the alarm will automatically switch to bat

Pagina 11 - Installation

OperationNormal Operating CharacteristicsWhen you first power up the unit, the alarm will sound briefly to let youknow the unit is receiving power and

Pagina 12

QQuuiicckk SSeett UUpp GGuuiiddeeInnttrroodduuccttiioonnFFeeaattuurreess• Views• What CO alarms can and cannot doInstallationBattery InstallationBatte

Pagina 13

16OperationTesting the ElectronicsYYoouu sshhoouulldd tteesstt tthhee aallaarrmm oonnccee aa wweeeekk, following the directions listedbelow. If at

Pagina 14

17OperationHow to Know If Your Alarm is MalfunctioningYour alarm performs an internal self-diagnosis every 15 seconds to makesure that it is functioni

Pagina 15

18OperationHow to Care for Your AlarmTo keep your alarm in good working order, you must follow these simplesteps:• Test the alarm once a week by press

Pagina 16 - Battery Installation

19OperationPeak Level MemoryThe peak level feature is helpful in identifying CO occurrences below 30 PPM.Although the unit will not automatically disp

Pagina 17 - Battery Backup Operation

20Carbon MonoxideHome Safety TipsWhat You Can Do...• Buy only appliances approved by a nationally recognized testing laboratory.• Choose fuel-burning

Pagina 18

Be Aware of the Warning Signs of Carbon Monoxide:Clues You Can See...• Streaks of carbon or soot around the service door of your fuel-burning appli-a

Pagina 19 - Operation

What To Do When the Alarm Sounds22Determine if anyone in the household is experiencing symptoms of CO poison-ing. Many cases of reported CO poisoning

Pagina 20

If alarm signal sounds 4 quick “chirps”, 5 seconds off:1) Immediately move to fresh air - outdoors or by an opendoor or window. Check that all persons

Pagina 21

SpecificationsPower:120 V AC units: 60 Hz, Current 60 mA max. Sensor:Sensor calibrated at 150 ppm (±25 ppm).Temperature:Operating range: 4.4˚C (40˚F)

Pagina 22

SpecificationsHow the Unit Determines When to AlarmYour Bryant CO alarm uses advanced technology to monitorthe environment in your home and warn you o

Pagina 23

IMPORTANTTHIS CARBON MONOXIDE ALARM IS DESIGNED TODETECT CARBON MONOXIDE FROM ANY SOURCE OFIMPROPER OR MALFUNCTIONING APPLIANCES. IT IS NOTDESIGNED TO

Pagina 24

Your new Bryant carbon monoxide alarm is a sophisticated electronicdevice – yet very simple to understand. Basically, the unit will display a “0” if i

Pagina 25

AC Powered in Normal Stand-by OperationIf at any time you test the alarm and it does not perform as described, have it replaced immediately.DC Powered

Pagina 26

DC Powered in Battery Backup OperationIf at any time you test the alarm and it does not perform as described, have it replaced immediately.Handling• D

Pagina 27 - (CO) which can KILL YOU

• Do not disassemble or modify the battery pack under anycircumstances. Disassembling the battery can cause internalshorts, resulting in bulging/burst

Pagina 28 - Specifications

WARRANTY COVERAGE: THE MANUFACTURER WARRANTS TO THE ORIGINAL CONSUMERPURCHASER, THAT THIS PRODUCT WILL BE FREE OF DEFECTS IN MATERIAL AND WORK-MANSHIP

Pagina 29

The model number and assembly number can be found on the label onthe back of the alarm.FFoorr WWaarrrraannttyy SSeerrvviiccee::In many cases the quick

Pagina 30 - Display Readings

Quick Set Up GuideStep 1Determine the best location for your CO alarm(s). Usually this is in or near bedrooms. The alarm should be located where it ca

Pagina 31

Step 5If the battery pack has a full charge when first powered up, you willsee three eights in the digital display indicating the alarm is warmingup.

Pagina 32

This Bryant carbon monoxide (CO) alarm is an important part of yourfamily’s home safety plan. As a new owner of a CO alarm, there aresome basic facts

Pagina 33

FeaturesTEST-RESETPEAK LEVELCarbon MonoxideALARMPARTS PER MILLION OF CO(Lb = Low or No Battery)AlarmSounderDigitalDisplayTest/ResetButtonBlinkingRed D

Pagina 34 - Limited Warranty

FeaturesDigital DisplayThe continuous digital display shows you the level of carbon monoxide (if any) theunit is sensing. The unit updates the digital

Pagina 35

FeaturesRear view with back door removedPowerCordAdapter CordStrain ReliefNote:Your Bryant CO alarm is NOT battery operated.The backup battery is to s

Comentarios a estos manuales