—6—
352AAV
COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE)
AND NON-DIRECT VENT (1-PIPE) APPLICATIONS
MAXIMUM ALLOWABLE PIPE LENGTH (FT)
ALTITUDE (FT)
UNIT MAX
INPUT RATE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN.)*
PIPE DIA
(IN.)*
12 3 4 5 6
0 to 2000
60,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 20 15 10 5 NA NA
2 2 70 70 70 70 70 70
80,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 10 NA NA NA NA NA
22555035 30 3020
2-1/2 2-1/2 70 70 70 70 70 70
100,000
2 Pipe or 3-in
Concentric
2 2 5 NANANANANA
2-1/2 2-1/2 40 30202010NA
3370 70 70 70 70 70
120,000
2 Pipe or 3-in.
Concentric
2-1/2 one disk 2-1/2 10 NA NA NA NA NA
3†NA454035 302520
3†nodisk 3† 707070707070
ALTITUDE (FT)
UNIT MAX
INPUT RATE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN.)*
PIPE DIA
(IN.)*
12 3 4 5 6
2001 to 3000
60,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 17 12 7 NA NA NA
2 2 70 67 66 61 61 61
80,000
2 Pipe or 2-in
Concentric
2 2 49 44 30252515
2-1/2 2-1/2 70 70 70 70 70 70
100,000
2 Pipe or 3-in
Concentric
2-1/2 2-1/2 35261616 6 NA
33
70 70 70 70 66 61
120,000
2 Pipe or 3-in.
Concentric
3 NA 14 9 NANANANA
NA 3†63 62 62 61 61 61
3†nodiskNA707063 56 50 43
4† no disk4†nodisk 707070707070
ALTITUDE (FT)
UNIT MAX
INPUT RATE
(BTUH)
DIRECT VENT (2-PIPE) ONLY
NON-DIRECT VENT
(1-PIPE) ONLY
NUMBER OF 90° ELBOWS
TERMINATION
TYPE
PIPE DIA
(IN)*
PIPE DIA
(IN.)*
12 3 4 5 6
3001 to 4000
60,000
2 Pipe or 2-in
Concentric
1-1/2 1-1/2 16 11 6 NA NA NA
226863 62 57 57 56
80,000
2 Pipe or 2-in
Concentric
2 2 46 41 28 23 22 13
2-1/2 2-1/2 707070707070
100,000
2 Pipe or 3-in
Concentric
2-1/2 2-1/2 33 24 15 14 5 NA
3370 70 70 66 61 56
120,000
2 Pipe or 3-in.
Concentric
3†nodisk NA 6558514438 31
NA 3† 595958575756
4† no disk 4†nodisk 4†nodisk 707070707070
See notesat end of table