Rated Maximum Continuous Power Capacity (LP) . . . . . . . . . . . . . .15,000 Watts*
Rated Maximum Continuous Power Capacity (NG) . . . . . . . . . . . . .13,000 Watts*
Rated Voltage..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120/240
Rated Maximum Continuous Load Current
120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108.3 NG/125.0 LP
240 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54.2 NG/62.5 LP
Main Line Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Amp
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Number of Rotor Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Rated AC Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Hz
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Battery Requirement (not included) . . . . . . . . . . . . . . . . . . . . . . . . . . .Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
Generator Weight (lbs.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .487
Dimensions (L” x W” x H”).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 x 24 x 28-1/4
J
ENGINE
Type of Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OHVI V-TWIN
Number of Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Rated Horsepower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 @ 3,600 rpm
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .992cc
Cylinder Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum w/Cast
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Iron Sleeve
Valve Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overhead Valve
Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Solid-state w/Magneto
Compression Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.5:1
Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Vdc
Oil Capacity Including Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 1.7 Qts.
Operating RPM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,600
Fuel Consumption
Natural Gas cu.ft./hr.
1/2 Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
Full Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220
Liquid Propane ft
3
/hr(gal/hr)
1/2 Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 (1.58)
Full Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88 (2.40)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water
column for natural gas, 11 to 14 inches of water column for LP gas
CONTROLS
Model Switch
- Auto Automatic Start on Utility failure/7 day
exerciser
- Off Stops unit. Power is removed control and
charger still operate
- Manual/Test (start) Start with starter control, unit stays on.
If utility fails, transfer to load takes place.
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest
(90 sec. maximum duration)
Engine Warm-up . . . . . . . . . . . . . . . . . . . . . . .10 seconds
Engine Cool-Down . . . . . . . . . . . . . . . . . . . . .1 minute
Starter Lock-out Starter cannot re-engage until 5 sec.
after engine has stopped.
2.5 Amp Timed Trickle Battery Charger . . . . . . . . . . . . . . . . . . .Standard
Automatic Voltage Regulator w/Overvoltage Protection . . . . . . .Standard
Automatic Low Oil Pressure Shutdown . . . . . . . . . . . . . . . . . . . .Standard
Overspeed Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard, 72Hz
High Temperature Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard
Overcrank Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard
Safety Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). Prime (Unlimited Running Time): Unit not recommended for prime power applications. Applicable for supplying electric power in lieu of commercially purchased power. Prime power is
the maximum power available at variable load. A 10% overload capacity is available for 1 hour in 12 hours. (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271). * Maximum wattage and
current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea
level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
HOME STANDBY SPECIFICATIONS Home Standby - 15kW
ENGINE
• Durable (OHVI) Design: Maximizes engine “breathing” for increased fuel efficiency.
Cylinder walls run cooler, reducing oil consumption. Because heat is the primary
cause of engine wear, the OHVI has a significantly longer life than competitive engines.
• ”Spiny-lok” cast iron cylinder walls: Rigid construction and added durability provide
long engine life.
• Electronic ignition, spark advance and compression release: These features
combine to assure smooth, quick starting every time.
• Full pressure lubrication system: Superior lubrication to all vital bearings means
better performance, less maintenance and significantly longer engine life.
• Low oil pressure shutdown system: Superior shutdown protection prevents
catastrophic engine damage due to low oil.
• High temperature shutdown: Prevents damage due to overheating.
GENERATORS
• Revolving field: Allows for smaller, light weight unit that operates 25% more
efficiently than a revolving armature generator.
• Skewed stator: Produces a smooth output waveform for compatibility with
electronic equipment.
• Displaced phase excitation: Maximizes motor starting capability. Provides more
surge capability than brushless generator designs.
• Automatic voltage regulation: Regulates the output voltage to ±2% prevents
damaging voltage spikes.
• UL 2200 Listed: For your safety
TRANSFER SWITCH - Not included.
MICROPROCESSOR CONTROL
• Manual/Auto/Off switch: Selects the operating mode.
• Utility voltage sensing: Constantly monitors utility voltage, setpoints 60% dropout,
80% pick-up, of standard voltage.
• Utility interrupt delay: Prevents nuisance start-ups of the engine, set point
approximately 15 seconds.
• Engine warm-up: Ensures engine is ready to assume the load, setpoint
approximately 10 seconds.
• Engine cool-down: Allows engine to cool prior to shutdown, setpoint approximately
1 minute.
• Seven day exerciser: Operates engine to prevent oil seal drying and damage
between power outages.
• Timed Trickle Battery charger: Maintains battery amperage to insure starting.
• Main Line Circuit Breaker: Protects generator from overload.
UNIT
• Weather protective enclosure: Ensures protection against mother nature. Hinged
key locking roof panel for security. Electrostatically applied epoxy paint for durability.
• Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the
unit to prevent injuries.
• Small, compact, attractive: Makes for an easy, eye appealing installation.
INSTALLATION
• Composite Mounting Pad: No need to pour concrete. Withstands years of exposure
to the elements.
BRYANT, INC. • 7310 WEST MORRIS STREET • INDIANAPOLIS, IN 46231 • www.bryant.com
Printed in USA 9.05 CATALOG NO. SS-ASPAX15-01 All specifications are subject to change without notice.
Comentarios a estos manuales