19
A07218
Fig. 13 -- Cover on Equipment Control Module
14. Turn on power to equipment. On power up, all display segments will
light for 5 sec. For the next 5 sec a 2--digit code appears on large display
which identifies AC/HP Control configuration. Refer to Option 33.
a. AC 1--stage air conditioner, AC, HP
b. HP 1 --stage heat pump, HP only
c. H heating only system, AC, HP
d. C cooling only system, AC, HP
Single--Piece Installation
The following steps should be followed for the installation of the single--piece
configuration.
1. Remove cover from Equipment Control Module by pressing the two tabs
on the bottom edge and pulling away . Route wires through large hole in
Equipment Control Module. Level Equipment Control Module against