Step #5 Jumper Configuration
FAN W/ HEAT
HEAT PUMP
1
2
3
1 2 3
J1
J2
Jumper and Jumper are used to select
heat pump operation. Note: Thermostat
Does Not Have Auxiliary Heat / Emergency
Heat Capability. Leave jumpers in original
factory default positions (figure-A) for non
heat pump applications.
Figure-C)
OUTPUTS
No Demand With Demand
Cooling Mode
Heating Mode
O*
Y, G, O*
B**
Y , G, B**
* Output active in Cooling
** Output active in Heating
Y active in Heating