MODEL PA13
AIR CONDITIONER
1 AND 3 PHASE
1-1/2 – 5 TONS (018-060)
Product Data
FEATURES
AVAILABLE SIZES:
Nominal sizes are available from 018 through
060 to meet the needs of residential and light
commercial applications.
CERTIFICATION:
All models are listed with UL,
(U.S. and
Canada), ARI, and CEC.
ELECTRICAL RANGE:
Units offered in 208/230v, single phase are
018-060, three phase 208/230v in 036, 048
and 060, and three phase 460v in 060.
FAN MOTOR:
The totally enclosed fan motor provides
greater reliability under adverse conditions
and dependable performance for many years.
The permanent split capacitor type motor was
designed for optimum efficiency. The motor
was then qualified under extreme conditions
to help ensure a long, reliable life.
CABINET:
A weather protective cabinet of prepainted
steel is protected underneath by a galva-
nized coating and treated with a layer of zinc
phosphate for a finish that will last for many
years. All screws on cabinet exterior are
coated for a long-lasting, rust-resistant, qual-
ity appearance.
UNIT DESIGN:
The copper tube, enhanced sine wave, alumi-
num fin coil is de-signed for optimum heat
transfer. Vertical air discharge carries sound
and hot condenser air up and away from adja-
cent patio areas and foliage. The base pan is
designed for easy removal of water, dirt, and
leaves.
COMPRESSOR:
Each compressor is protected with internal
temperature- and current-sensitive overloads.
An internal pressure relief valve provides high-
pressure protection to the refrigerant system.
For improved serviceability, all models are
equipped with a compressor terminal plug.
SERVICE VALVES:
Both service valves are brass, front seating
type with sweat connections. Valves are exter-
nally located so refrigerant tube connections
can be made quickly and easily. Each valve
has a service port for ease of checking oper-
ating refrigerant pressures.
SERVICEABILITY:
One access panel provides access to electri-
cal controls. Removal of top gives access to
fan motor, compressor, and condenser coil.
Vista de pagina 0
1 2 3 4 5 6 ... 13 14

Indice de contenidos

Pagina 1 - Product Data

MODEL PA13AIR CONDITIONER1 AND 3 PHASE1-1/2 – 5 TONS (018-060) Product Data FEATURES AVAILABLE SIZES: Nominal sizes are available from 018 through060

Pagina 2 - MODEL NUMBER NOMENCLATURE

—10—PA13 DETAILED COOLING CAPACITIES* See notes on page 13. EVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115CFM EWBCapacityMBtuh†T

Pagina 3 - SPECIFICATIONS

—11—PA13 DETAILED COOLING CAPACITIES* See notes on page 13. EVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115CFM EWBCapacityMBtuh†T

Pagina 4 - SPECIFICATIONS Continued

—12—PA13 DETAILED COOLING CAPACITIES* See notes on page 13. EVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115CFM EWBCapacityMBtuh†T

Pagina 5

—13—PA13 DETAILED COOLING CAPACITIES* Continued * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation, per ARI Sta

Pagina 6

—14— © Payne Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 04/06 Catalog No. SS-PA13-01Manu

Pagina 7 - A-WEIGHTED SOUND POWER (dBA)

—2—PA135. OPTIONAL DENSE GRILLE SHOWN IN DRAWING. MODEL NUMBER NOMENCLATURE PA13 N RType of Unit PA13 – Electric Air Conditioner Electrical Su

Pagina 8 - RATINGS AND PERFORMANCE

—3—PA13 SPECIFICATIONS See notes on page 4. UNIT SIZE 018 024 030 036 SERIES C C C C ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—3Opera

Pagina 9

—4—PA13 SPECIFICATIONS Continued N/A—Not applicable in this application.* Permissible limits of the voltage range at which unit will operate satisfac

Pagina 10 - DETAILED COOLING CAPACITIES*

—5—PA13 OPTIONAL EQUIPMENT USAGE GUIDELINE * For tubing line sets greater than 80 ft horizontal and/or 20 ft vertical differential, refer to Resident

Pagina 11

—6—PA13 ACCESSORY DESCRIPTION AND USAGE (continued) 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit ser

Pagina 12

—7—PA13 A-WEIGHTED SOUND POWER (dBA) NOTE: Tested in accordance with ARI standard 270.95 (Not listed with ARI) METERING DEVICE * TXV must be ordered

Pagina 13

—8—PA13 RATINGS AND PERFORMANCE UNITSIZE-SERIESINDOORMODELTOTAL CAPACITYBTUHFACTORY- SUPPLIED ENHANCE-MENTSEEREERSTANDARD RATINGPAYNE GAS FURNACE OR

Pagina 14 - SYSTEM DESIGN

—9—PA13 042-C PF1MNC043 41,000 TDR&TXV 14.00 — 12.00PF1MNC049 41,500 TDR&TXV 14.00 — 12.00 048-C *CAR**4821A** 46,000 TXV — 13.00 11.00CAR**4