Bryant T2-NHP Manual de instrucciones Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
8
5. Drill two 3/16--in. mounting holes in wall where marked.
6. Secure mounting base to wall with 2 anchors and screws provided
(additional anchoring holes available for more secure mounting if needed)
making sure all wires extend through hole in mounting base.
7. Adjust length and routing of each wire to reach proper terminal and
connector block on mounting base with 1/4 in. of extra wire. Strip only
1/4 in. of insulation from each wire to prevent adjacent wires from
shorting together when connected. See Fig. 2.
A07155
Fig. 2 -- Secure Wires to Terminal Strip
8. Matc h and connect equipment wir es to prope r terminals of the conne ct or
blocks (se e Fi g. 3). I f t he re are sepa ra te 24VAC t r ansforme rs , one in the
indoor unit and one in the outdoor unit , conne ct the comm on of each to the
C termi nal. Remove f a ctory--inst a ll ed jum per wire from Rc and Rh termi nals.
Connect the R from the indoor unit to the Rh te rmi nal. Connect the R from
the outdoor unit to the Rc terminal. Then the W signal is take n fr om the Rh
powe r and the Y, G and O signals ar e ta ken from the Rc power.