
—14—
PH13
HEAT PUMP HEATING PERFORMANCE Continued
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3 7 172737475767
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
EDB CFM Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW†
PH13NR036-C Outdoor Section With PF1MNC037 Indoor Section
65
1050 15.65 14.40 2.44 19.05 17.50 2.45 22.71 20.71 2.46 26.69 23.70 2.49 31.14 28.33 2.54 36.05 36.05 2.60 41.07 41.07 2.63 45.66 45.66 2.67
1200 15.96 14.68 2.49 19.37 17.80 2.49 23.07 21.03 2.49 27.06 24.04 2.51 31.56 28.72 2.54 36.43 36.43 2.57 40.90 40.90 2.59 45.03 45.03 2.61
1350 16.24 14.95 2.54 19.66 18.07 2.53 23.39 21.32 2.52 27.42 24.35 2.54 31.92 29.05 2.56 36.52 36.52 2.57 40.50 40.50 2.58 44.36 44.36 2.58
70
1050 15.30 14.08 2.53 18.74 17.22 2.55 22.40 20.42 2.56 26.35 23.40 2.59 30.75 27.98 2.64 35.60 35.60 2.70 40.87 40.87 2.75 45.63 45.63 2.79
1200 15.61 14.36 2.58 19.07 17.52 2.59 22.74 20.73 2.59 26.74 23.74 2.61 31.17 28.37 2.64 36.07 36.07 2.70 40.82 40.82 2.70 45.15 45.15 2.73
1350 15.91 14.64 2.63 19.36 17.79 2.63 23.06 21.03 2.62 27.07 24.04 2.63 31.54 28.70 2.66 36.36 36.36 2.68 40.59 40.59 2.69 44.60 44.60 2.70
75
1050 14.93 13.74 2.63 18.42 16.92 2.65 22.10 20.15 2.67 26.05 23.13 2.70 30.37 27.64 2.75 35.15 35.15 2.81 40.54 40.54 2.87 45.53 45.53 2.91
1200 15.25 14.03 2.67 18.74 17.22 2.69 22.44 20.46 2.69 26.41 23.46 2.71 30.79 28.02 2.75 35.63 35.63 2.80 40.70 40.70 2.82 45.19 45.19 2.85
1350 15.54 14.30 2.73 19.04 17.50 2.73 22.75 20.74 2.72 26.74 23.75 2.74 31.16 28.36 2.77 36.04 36.04 2.80 40.60 40.60 2.81 44.75 44.75 2.82
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Heating
Indoor
Section
Unit
Size
Heating
Capacity Power Capacity Power
PF1MNC 037 1.00 1.00 — — — —
043 1.01 0.95
See notes on page 15.
PH13NR042-C Outdoor Section With PF1MNC043 Indoor Section
65
1225 19.66 18.08 2.78 23.46 21.55 2.85 27.54 25.11 2.92 32.06 28.48 3.02 37.04 33.71 3.15 42.52 42.52 3.31 48.83 48.83 3.53 55.14 55.14 3.71
1400 20.03 18.43 2.84 23.84 21.91 2.90 27.96 25.49 2.96 32.53 28.89 3.05 37.57 34.19 3.16 43.09 43.09 3.31 49.22 49.22 3.48 54.83 54.83 3.65
1575 20.39 18.76 2.91 24.21 22.25 2.95 28.36 25.85 3.01 32.95 29.27 3.09 38.02 34.60 3.20 43.58 43.58 3.35 49.23 49.23 3.48 54.32 54.32 3.64
70
1225 19.31 17.77 2.89 23.16 21.29 2.96 27.20 24.80 3.04 31.65 28.11 3.14 36.59 33.30 3.27 42.00 42.00 3.44 48.22 48.22 3.66 54.81 54.81 3.87
1400 19.70 18.12 2.95 23.55 21.64 3.01 27.62 25.19 3.08 32.12 28.52 3.17 37.11 33.77 3.29 42.57 42.57 3.44 48.83 48.83 3.64 54.76 54.76 3.80
1575 20.06 18.46 3.01 23.92 21.98 3.06 28.01 25.54 3.12 32.56 28.92 3.21 37.57 34.18 3.32 43.06 43.06 3.47 49.05 49.05 3.62 54.42 54.42 3.79
75
1225 18.92 17.41 2.99 22.86 21.01 3.08 26.92 24.54 3.17 31.29 27.79 3.27 36.17 32.92 3.41 41.50 41.50 3.58 47.64 47.64 3.80 54.42 54.42 4.05
1400 19.32 17.77 3.05 23.25 21.37 3.13 27.32 24.91 3.20 31.74 28.19 3.29 36.67 33.37 3.42 42.07 42.07 3.57 48.29 48.29 3.79 54.57 54.57 3.97
1575 19.69 18.12 3.12 23.62 21.70 3.18 27.69 25.25 3.24 32.16 28.56 3.33 37.12 33.78 3.44 42.55 42.55 3.59 48.71 48.71 3.78 54.41 54.41 3.94
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Heating
Indoor
Section
Unit
Size
Heating
Capacity Power Capacity Power
PF1MNC 043 1.00 1.00 — — — —
049 1.01 0.95
PH13NR048-C Outdoor Section With PF1MNC049 Indoor Section
65
1400 22.35 20.56 3.08 26.98 24.79 3.19 31.80 28.99 3.30 37.20 33.04 3.43 43.15 39.27 3.59 49.62 49.62 3.78 57.14 57.14 4.05 65.61 65.61 4.39
1600 22.67 20.85 3.10 27.30 25.08 3.19 32.16 29.32 3.28 37.61 33.41 3.39 43.64 39.71 3.53 50.20 50.20 3.71 57.82 57.82 3.96 65.86 65.86 4.18
1800 22.94 21.11 3.12 27.58 25.34 3.19 32.48 29.61 3.28 37.99 33.74 3.38 44.03 40.07 3.51 50.65 50.65 3.68 58.28 58.28 3.92 65.38 65.38 4.07
70
1400 21.81 20.06 3.22 26.54 24.39 3.34 31.40 28.63 3.46 36.72 32.62 3.60 42.61 38.78 3.76 49.00 49.00 3.96 56.41 56.41 4.24 64.78 64.78 4.59
1600 22.15 20.38 3.23 26.87 24.70 3.34 31.75 28.95 3.44 37.14 32.98 3.56 43.10 39.22 3.71 49.58 49.58 3.89 57.11 57.11 4.14 65.41 65.41 4.41
1800 22.44 20.65 3.25 27.16 24.96 3.35 32.04 29.22 3.43 37.49 33.29 3.54 43.50 39.58 3.68 50.05 50.05 3.86 57.62 57.62 4.10 65.29 65.29 4.28
75
1400 21.27 19.57 3.35 26.07 23.96 3.49 31.01 28.27 3.62 36.23 32.18 3.77 42.08 38.29 3.95 48.39 48.39 4.16 55.69 55.69 4.43 63.94 63.94 4.79
1600 21.60 19.87 3.36 26.41 24.27 3.49 31.35 28.59 3.60 36.65 32.55 3.73 42.56 38.73 3.89 48.96 48.96 4.08 56.39 56.39 4.33 64.74 64.74 4.66
1800 21.87 20.12 3.39 26.71 24.55 3.50 31.65 28.85 3.60 37.01 32.87 3.71 42.96 39.09 3.86 49.44 49.44 4.04 56.94 56.94 4.28 65.02 65.02 4.51
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Heating
Indoor
Section
Unit
Size
Heating
Capacity Power Capacity Power
PF1MNC 049 1.00 1.00 — — — —
061 1.01 0.97
Comentarios a estos manuales