97B0046N01
Revision: 21 Aug, 2007D
Horizontal & Vertical Packaged Products
Table of Contents
Model Nomenclature 2
Storage 3
Pre-Installation 3
Physical Data 4-5
Unit Dimensions 6-14
Horizontal Unit Installation 15
Field Conversion of Air Discharge 17
Condensate Piping Installation 18
Duct System Installation 18
Vertical Unit Installation 19
Water Connections 21
Ground Loop Applications 21-22
Open Loop - Ground Water Systems 23-24
Water Quality Standards 25
Hot Water Generator 26-27
Electrical - Line Voltage 28-29
Power Wiring 29-30
Electrical - Low Voltage Wiring 31
Low Water Temperature Cutout Selection 31
Water Valve Wiring 32
Thermostat Wiring 33-34
ECM Blower Control 35-36
Blower Data 37-39
Electrical Wiring Schematics 40-46
CXM Controls 47
CXM Safety Control Reset 48-50
Unit Start-Up and Operating Conditions 51
Unit and System Checkout Procedure 52
Unit Start-Up Procedure 52-53
Coax Pressure Drop Table 54
Operating Pressures 55-59
Preventive Maintenance 60
Troubleshooting 61-62
Functional & Performance Troubleshooting 63-64
Refrigerant Circuit Diagram 65
Warranty 67
Vista de pagina 0
1 2 3 4 5 6 ... 67 68

Indice de contenidos

Pagina 1 - Table of Contents

GT-PX (50YD) Two-Stage Puron® SeriesGT-PG (50YE) Single-Stage Puron® SeriesGT-G (50YC) Packaged R22 SeriesResidential Horizontal & VerticalPackage

Pagina 2 - Rev.: 08 Aug, 2007D

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D10DIMENSIONS — VERTICAL DOWNFLOW GT-PX (50YD) SERIES 2’ [61cm]

Pagina 3 - GENERAL INFORMATION

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D11DIMENSIONS — HORIZONTAL GT-PG (50YE) SERIES Right Return Str

Pagina 4 - UNIT PHYSICAL DATA

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D12DIMENSIONS — VERTICAL UPFLOW GT-G (50YC) SERIESOptional3’ Se

Pagina 5

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D13Access PanelsAux Htr Knock-OutPower SupplyLow VoltageExterna

Pagina 6 - Rev.: 21 Aug, 2007D

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D14DIMENSIONS — HORIZONTAL GT-G (50YC) SERIESBlower2’ ServiceUV

Pagina 7

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D15HORIZONTAL INSTALLATIONMounting Horizontal UnitsHorizontal u

Pagina 8

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D16HORIZONTAL INSTALLATION (by others) (by others)ThermostatWir

Pagina 9 - ASP=Alternate Service Panel

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D17Water Connection EndReturn AirRemove ScrewsWater Connection

Pagina 10 - (left opposite)

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D18*3/4" IPTTrap Depth1.5" [38mm]Min 1.5"[38mm]1

Pagina 11 - Unit Hanger Detail

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D19VERTICAL INSTALLATIONFlexible canvas ductconnector to reduce

Pagina 12 - Right Return

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D2MODEL NOMENCLATURE: GENERAL OVERVIEW FOR ALL H & V SERIES

Pagina 13

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D20VERTICAL INSTALLATIONSound Attenuation for Vertical UnitsSou

Pagina 14 - Right-Hand Return Air

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D21WATER CONNECTION INSTALLATIONExternal Flow Controller Mounti

Pagina 15 - HORIZONTAL INSTALLATION

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D22GROUND-LOOP HEAT PUMP APPLICATIONSTable 2: Antifreeze Percen

Pagina 16

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D23Unit PowerDisconnectFlowControllerInsulatedHose KitP/T Plugs

Pagina 17 - Back Discharge

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D24Air Pad orExtrudedpolystyreneinsulation boardUnit PowerDisco

Pagina 18 - DUCT SYSTEM INSTALLATION

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D25Water QualityParameterHXMaterialClosedRecirculatingOpen Loop

Pagina 19 - VERTICAL INSTALLATION

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D26HOT WATER GENERATORThe HWG (Hot Water Generator) or desuperh

Pagina 20

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D27InstallationThe HWG high limit temperature switch is set at

Pagina 21 - WATER CONNECTION INSTALLATION

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D28ELECTRICAL - LINE VOLTAGEWARNING! To avoid possible injury

Pagina 22

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D29ELECTRICAL - LINE VOLTAGECAUTION! Use only copper conductor

Pagina 23

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D3GENERAL INFORMATIONInspectionUpon receipt of the equipment, c

Pagina 24

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D30Figure 17: GT-PX/GT-PG Single Phase Line Voltage Field Wirin

Pagina 25 - WATER QUALITY STANDARDS

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D31ELECTRICAL - LOW VOLTAGE WIRINGFigure 20: GT-PX/GT-PG Low Vo

Pagina 26 - HOT WATER GENERATOR

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D32ELECTRICAL - LOW VOLTAGE WIRINGTerminal StripTypicalWaterVal

Pagina 27

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D33ELECTRICAL - THERMOSTAT WIRINGѥ CAUTION! ѥCAUTION! Many unit

Pagina 28 - ELECTRICAL - LINE VOLTAGE

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D34Note:1. Thermostat DIP switches must be confi gured for heat

Pagina 29 - ELECTRICAL - POWER WIRING

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D35ECM BLOWER CONTROLThe ECM fan is controlled by an interface

Pagina 30 - (see electrical table for

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D36ECM BLOWER CONTROLTable 5: ECM Board Tap SettingsCooling set

Pagina 31 - Figure 22: FP1 Limit Setting

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D37GT-PX (50YD) SERIES ECM BLOWER PERFORMANCE DATAGT-PG (50YE)

Pagina 32 - Figure 26: Two-Stage Piping

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D38GT-PG (50YE) SERIES ECM BLOWER PERFORMANCE DATANote: See pag

Pagina 33

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D39GT-G (50YC) SERIES PSC BLOWER PERFORMANCE DATAModelFanSpeedR

Pagina 34 - Rev.: 07/18/05D

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D4UNIT PHYSICAL DATAGT-PX Two-Stage (50YD) SeriesGT-PG Single-S

Pagina 35 - ECM BLOWER CONTROL

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D40GT-G (50YC) SERIES ECM BLOWER PERFORMANCE DATANote: See page

Pagina 36

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D41TYPICAL WIRING DIAGRAM - GT-PX/GT-PG UNITS WITH CXM BOARDAND

Pagina 37

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D42TYPICAL WIRING DIAGRAM - GT-PG UNITS WITH CXM BOARDAND PSC F

Pagina 38

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D43TYPICAL WIRING DIAGRAM - GT-G UNITS WITH CXM BOARDAND ECM FA

Pagina 39

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D44TYPICAL WIRING DIAGRAM - GT-G UNITS WITH CXM BOARDAND PSC FA

Pagina 40

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D45TYPICAL WIRING DIAGRAM - GT-PX & GT-PG UNITS WITH DXM BO

Pagina 41 - AND ECM FAN MOTOR

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D46TYPICAL WIRING DIAGRAM - GT-PG UNITS WITH DXM BOARD,PSC FAN

Pagina 42 - AND PSC FAN MOTOR

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D47CXM ControlFor detailed control information, see CXM/DXM App

Pagina 43

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D48CXM CONTROLSSafety Features – CXM ControlThe safety features

Pagina 44

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D49CXM Control Start-up OperationThe control will not operate u

Pagina 45

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D5GT-G Packaged (GT-G) SeriesUNIT PHYSICAL DATAModel 015 018 02

Pagina 46

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D50CXM CONTROLSCXM Thermostat DetailsThermostat Compatibility -

Pagina 47 - CXM CONTROLS

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D51UNIT STARTING AND OPERATING CONDITIONSOperating LimitsEnviro

Pagina 48

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D52CAUTION! Verify that ALL water control valves are open and

Pagina 49

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D53WARNING! When the disconnect switch is closed, high voltage

Pagina 50

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D54Table 9a: GT-PX Coax Water Pressure Drop Table 9b: GT-PG Coa

Pagina 51 - Table 8: Operating Limits

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D55UNIT OPERATING CONDITIONSTable 11: GT-PX Series Typical Unit

Pagina 52

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D56UNIT OPERATING CONDITIONSTable 12: GT-PG Series Typical Unit

Pagina 53 - UNIT START-UP PROCEDURE

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D57UNIT OPERATING CONDITIONSTable 12: GT-PG Series Typical Unit

Pagina 54 - UNIT OPERATING CONDITIONS

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D58UNIT OPERATING CONDITIONSTable 12: GT-PG Series Typical Unit

Pagina 55

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D59UNIT OPERATING CONDITIONSTable 13: GT-G Series Typical Unit

Pagina 56

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D6Access PanelsTop View-Left ReturnTop View-Right ReturnURSIsom

Pagina 57

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D60PREVENTIVE MAINTENANCEWater Coil Maintenance(Direct ground w

Pagina 58

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D61GeneralIf operational diffi culties are encountered, perform

Pagina 59

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D62See “Does not Operate in Clg”See “Only Comp Runs”StartDid Un

Pagina 60 - PREVENTIVE MAINTENANCE

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D63Fault Htg Clg Possible Cause SolutionMain power Problems X X

Pagina 61 - TROUBLESHOOTING

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D64Only Compressor Runs X X Thermostat wiringCheck G wiring at

Pagina 62 - Troubleshooting Chart

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D65TROUBLESHOOTING FORMCOAXCOMPRESSORDISCHARGESUCTIONHWGCOOLING

Pagina 63 - FUNCTIONAL TROUBLESHOOTING

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D66NOTES

Pagina 64 - PERFORMANCE TROUBLESHOOTING

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D67WARRANTYCARRIER CORPORATION LIMITED EXPRESS WARRANTY/LIMITAT

Pagina 65 - TROUBLESHOOTING FORM

97B0046N01The Manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time for order

Pagina 66

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D7DIMENSIONS — VERTICAL DOWNFLOW GT-PX (50YD) SERIES 12345 J K

Pagina 67 - WARRANTY

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D8DIMENSIONS — HORIZONTAL GT-PX (50YD) SERIES12345 J K LA B C D

Pagina 68 - *97B0046N01*

Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D9DIMENSIONS — VERTICAL UPFLOW GT-PG (50YE) SERIESAccess Panels

Comentarios a estos manuales