Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D
16
HORIZONTAL INSTALLATION
(by others)
(by others)
Thermostat
Wiring
Optional Balancing Valve
Water In
Water Out
Optional Low Pressure Drop Water
Control Valve
(can be internally mounted
on some models)
Ball Valve with optional
integral P/T plug
Stainless steel braid hose
with integral "J" swivel
Building
Loop
Unit Power
Disconnect
Power Wiring
Insulated supply duct with
at least one 90 deg elbow
to reduce air noise
Return Air
Supply Air
Unit Hanger
3/8" [10mm] threaded rods
Unit Power
Flexible Duct
Connector
Figure 3: Typical Horizontal Unit Installation
Air Coil
To obtain maximum performance, the air coil should be
cleaned before start-up. A 10% solution of dishwasher
detergent and water is recommended for both sides
of the coil. A thorough water rinse should follow. UV
based anti-bacterial systems may damage e-coated
air coils.
NOTICE! Failure to remove shipping brackets
from spring-mounted compressors will cause
excessive noise, and could cause component
failure due to added vibration.