Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D
2
MODEL NOMENCLATURE: GENERAL OVERVIEW FOR ALL H & V SERIES
NOTE: Above model nomenclature is a general reference. Consult individual specifi cation catalogs for detailed information.
WARNING! Verify refrigerant type before
proceeding. Units are shipped with Puron®
(R410A), R22 and R407c refrigerants. The
unit label will indicate which refrigerant is
provided. The Puron® Application Guideline
and Service Manual should be read and
understood before attempting to service
refrigerant circuits with Puron® refrigerant.
WARNING! To avoid the release of
refrigerant into the atmosphere, the
refrigerant circuit of this unit must be serviced
only by technicians who meet local, state,
and federal profi ciency requirements.
WARNING! All refrigerant discharged
from this unit must be recovered WITHOUT
EXCEPTION. Technicians must follow industry
accepted guidelines and all local, state, and
federal statutes for the recovery and disposal
of refrigerants. If a compressor is removed
from this unit, refrigerant circuit oil will
remain in the compressor. To avoid leakage
of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION!
To avoid equipment damage,
DO NOT use these units as a source of
heating or cooling during the construction
process. The mechanical components and
fi lters will quickly become clogged with
construction dirt and debris, which may
cause system damage.
ѥ WARNING! ѥ
ѥ WARNING! ѥ
ѥ WARNING! ѥ
ѥ CAUTION! ѥ
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation,
which if not avoided will result in death or serious injury.
DANGER labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation,
which if not avoided could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation or
an unsafe practice, which if not avoided could result in
minor or moderate injury or product or property damage.
NOTICE: Notifi cation of installation, operation or
maintenance information, which is important, but which is
not hazard-related.
Rev.: 08 Aug, 2007D
NOTE: Some options/configurations not available on all series. Please consult Specification Catalogs for model specific options.
C = CXM
BACK
RIGHT
LEFT
LEFT
E
S
DISCHARGEOPTION
HORIZONTAL
RETURN
LEFT
BACK
Z
B
RIGHT
RIGHT
RIGHT
LEFT
R
L
DOWN
DOWN
RETURN
VERTICAL DOWNFLOW
OPTION DISCHARGE
048
072
060
036
042
030
YC = GT-G SINGLE-STAGE R22 REFRIG
YD = GT-PX TWO-STAGE PURON® REFRIG
024
018
3 = 208V, 230V/1PH/60Hz
CONTROLS:
HEAT EXCHANGER OPTIONS:
SIZE:
AIR FLOW CONFIGURATION - PSC:
VOLTAGE:
REVISION LEVEL:
PACKAGING:
1211109
13A
86754
C04
DISCHARGE
1 = SINGLE PACK, DOMESTIC
321
YEV05
OPTION
YE = GT-PG SINGLE-STAGE PURON® REFRIG
UNIT TYPE:
VERTICAL UPFLOW
RETURN
TOP
TOP
L
R
LEFT
RIGHT
0 = CURRENT REVISION
2
L
0
BACK
RIGHT
LEFT
LEFT
Y
W
DISCHARGEOPTION
HORIZONTAL 50YD/50YE ONLY*
RETURN
LEFT
BACK
N
P
RIGHT
RIGHT
RIGHT
LEFT
K
J
DOWN
DOWN
RETURN
VERTICAL DOWNFLOW 50YD/50YE ONLY*
OPTION DISCHARGE
AIR FLOW CONFIGURATION - ECM:
DISCHARGEOPTION
VERTICAL UPFLOW 50YD/50YE ONLY*
RETURN
TOP
TOP
J
K
LEFT
RIGHT
MOTOR
PSC
PSC
PSC
PSC
PSC
PSC
PSC
PSC
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
ECM
ECM
ECM
ECM
ECM
ECM
ECM
ECM
D = VERTICAL DOWNFLOW
H = HORIZONTAL
V = VERTICAL UPFLOW
CONFIGURATION:
E = CXM + ECM (50YC ONLY)
USE PSC CONFIGURATION FOR 50YC SERIES AND SELECT CONTROL OPTION "E"
STANDARD
COATED AIR COIL
COPPER CUPRO-NICKEL
A
B
J
K
W/HOT WATER GENERATOR
RF
WHOLE HOUSE DEHUMIDIFICATION
LM
WHOLE HOUSE DEHUMIDIFICATION
W/HOT WATER GENERATOR
Comentarios a estos manuales