PERFORMANCE DATA (CONT)
LEGEND
BF— B y pass Factor
edb— Entering Dry---Bulb
Ewb Entering Wet--- Bulb
kW Total Unit Power Input
ldb— Leaving Dry---Bulb
lwb Leaving Wet--- Bulb
SHC Sensible Heat Capacity (1000 Btuh)
TC Total Capacity (1000 Btuh) (net)
ECM Electronic Computated Motor
*At 75_F (23.85C ) entering dry bulb (Tennessee Valley Authority
[TVA] rating conditions); all other at 80_F (26.6_C) entering dry
bulb.
NOTES:
1. Ratings are net; they account for the effects of the
evaporator--- fan motor power and heat.
2. Direct interpolation is permissible. Do not extrapolate.
3. The following formulas may be used:
Sensible capacity (Btuh)
1.10 x cfm
t
ldb =
t
edb
--
Wet---bulb temperature corresponding to enthalpy
air leaving evaporator coil (
h
lwb)
t
lwb =
total capacity (Btuh)
4.5 x cfm
h
lwb =
h
e w b ---
Where:
h
ewb = Enthalpy of air entering evaporator coil
4. The SHC is based on 80_F (26.65C) edb temperature of air
entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr
factor x cfm) from SHC.
Above 80_F (26.6_C) edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 + BF) x (edb --- 80).
Natural Gas Orifice Sizes and Manifold Pressure (in. W.C.)
Nameplate
Input,
High Stage
(Btu/hr)
ALTITUDE OF INST ALLATION (FT. [m] ABOVE SEA LEVEL) U .S.A.*
0 to 2000
[0 to 610]
2001 to
3000*
[610 to 914]
3001 to 4000
[915 to 1219]
4001 to 5000
[1220 to 1524]
5001 to 6000
[1524 to 1829]
40000
Orifice No. (Qty) 44 (2) 45 (2)† 48 (2)† 48 (2)† 48 (2)†
Manifold Press. High / Low 3.2 /1.4 3.2 /1.4 3.8 /1.6 3.5 /1.5 3.2 /1.4
60000
Orifice No. (Qty) 44 (3) 45 (3)† 48 (3)† 48 (3)† 48 (3)†
Manifold Press. High / Low 3.2 /1.4 3.2 /1.4 3.8 /1.6 3.5 /1.5 3.2 /1.4
90000
Orifice No. (Qty) 38 (3) 41 (3)† 41 (3)† 42 (3)† 42 (3)†
Manifold Press. High / Low 3.6 /1.6 3.8 /1.6 3.4 /1.5 3.4 /1.5 3.2 /1.4
115000
Orifice No. (Qty) 33 (3) 36 (3)† 36 (3)† 36 (3)† 38 (3)†
Manifold Press. High / Low 3.8 /1.7 3.8 /1.7 3.6 /1.6 3.3 /1.4 3.6 /1.5
130000
Orifice No. (Qty) 31 (3) 31 (3) 33 (3)† 33 (3)† 34 (3)†
Manifold Press. High / Low 3.8 /1.7 3.2 /1.4 3.7 /1.6 3.4 /1.4 3.3 /1.4
*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.
In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion stationor
dealer.
For Canadian Installations from 2000 to 4500 ft (611 to 1372 m), use U.S.A. column 2001 to 3000 ft (610 to 914 m).
† Orifices available through your distributor.
NOTE: Orifice sizes and manifold pressure settings are based on natural gas with a heating value of 1025 Btu/ft
3
and a specific gravity of .6.
Propane Gas Orifice Sizes and Manifold Pressure (in. W.C.)
Nameplate
Input,
High Stage
(Btu/hr)
ALTITUDE OF INST ALLATION (FT. [m] ABOVE SEA LEVEL) U .S.A.*†
0 to 2000
[0 to 610]
2001 to 3000*
[610 to 914]
3001 to 4000
[915 to 1219]
4001 to 5000
[1220 to 1524]
5001 to 6000
[1524 to 1829]
40000
Orifice No. (Qty) 55 (2) 56 (2) 56 (2) 56 (2) 56 (2)
Manifold Press. High / Low 10.0/5.0 11.0/6.0 11.0/5.5 11.0/5.0 10.7/4.8
60000
Orifice No. (Qty) 55 (2) 56 (2) 56 (2) 56 (2) 56 (2)
Manifold Press. High / Low 10.0/5.0 11.0/6.0 11.0/5.5 11.0/5.0 10.7/4.8
90000
Orifice No. (Qty) 53 (3) 54 (3) 54 (3) 54 (3) 54 (3)
Manifold Press. High / Low 10.0/5.4 11.0/6.4 11.0/5.9 11.0/5.4 11.0/5.0
115000
Orifice No. (Qty) 51 (3) 52 (3) 52 (3) 53 (3) 53 (3)
Manifold Press. High / Low 10.0/5.4 11.0/5.0 10.6/4.8 11.0/6.1 11.0/5.5
130000
Orifice No. (Qty) 49 (3) 50 (3) 51 (3) 52 (3) 52 (3)
Manifold Press. High / Low 10.0/5.4 11.0/4.8 11.0/4.9 11.0/5.2 11.0/5.0
*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.
In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion stationor
dealer.
For Canadian Installations from 2000 to 4500 ft (611 to 1372 m), use U.S.A. column 2001 to 3000 ft (610 to 914 m).
Use Kit No. CPLPCONV013A00 (0--- 2000 ft [0--- 610 m] above sea level. Use Kit No. CPLPCONV014A00 (2001---6000 ft [611--- 1829 m] abo ve sea level.