PERFORMANCE DATA (CONT)
Wet/Dry Coil Air Delivery (CFM)-- Low Stage
208/230 VOLT
UNIT
SIZE
SYSTEM SETTING
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
24
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 525 525 525 525 525 525 525 525 525 525
MAX 600 600 600 600 600 600 600 600 600 600
30
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 613 613 613 613 613 613 613 613 613 613
MAX 700 700 700 700 700 700 700 700 700 700
36
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 743 743 743 743 743 743 743 743 743 743
MAX 850 850 850 850 850 850 850 850 850 850
42
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 853 853 853 853 853 853 853 853 853 853
MAX 975 975 975 975 975 975 975 975 975 975
48
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 963 963 963 963 963 963 963 963 963 963
MAX 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
60
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
MAX 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372
Wet/Dry Coil Air Delivery (CFM)-- High Stage
208/230 VOLT
UNIT
SIZE
SYSTEM SETTING
EXTERNAL STA TIC PRESSURE IN. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
24
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 700 700 700 700 700 700 700 700 700 700
MAX 800 800 800 800 800 800 800 800 800 800
30
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 875 875 875 875 875 875 875 875 875 875
MAX 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
36
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050
MAX 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
42
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225
MAX 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400
48
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400
MAX 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600
60
COMFORT (Default) Variable based on C omfort Settings
EFFICIENCY 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750
MAX 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
Air delivery values are based on operating voltage of 230v, and wet coil. Filter an d electric h ea ter will n ot change air delivery valu es.
NOTES:
1. See User Interface instructions for more information on Max, Efficiency, and Comfort Settings
2. E fficiency Setting operates at 350 cfm/ton (nominal) an d Max Setting operates at 400 CFM/ton (n ominal)
577D-- -- A